Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 19(1): e0296521, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38180994

RESUMO

BACKGROUND: Evaluating immune responses following COVID-19 vaccination is paramount to understanding vaccine effectiveness and optimizing public health interventions. This study seeks to elucidate individuals' immune status after administering a second dose of diverse COVID-19 vaccines. By analyzing immune responses through serological markers, we aim to contribute valuable insights into the uniformity of vaccine performance. METHODS: A total of 80 participants were enrolled in this study, with demographic and COVID-19 infection-related data collected for categorization. Serum samples were acquired within a specified timeframe, and SARS-CoV-2 IgM/IgG rapid tests were conducted. Moreover, CTLA-4 levels were measured through ELISA assays, allowing us to assess the immune responses comprehensively. The participants were divided into eight groups based on various factors, facilitating a multifaceted analysis. RESULTS: The outcomes of our investigation demonstrated consistent immune responses across the diverse types of COVID-19 vaccines administered in Iraq. Statistical analysis revealed no significant distinctions among the vaccine categories. In contrast, significant differences were observed in CTLA-4 among the control group (non-infected/non-vaccinated, infected/non-vaccinated) and infected/Pfizer, non-infected/Pfizer, and infected/Sinopharm, non-infected/sinopharm (P = 0.001, < 0.001, 0.023, respectively). This suggests that these vaccines exhibit comparable effectiveness in eliciting an immune response among the study participants. CONCLUSIONS: In conclusion, our study's results underscore the lack of discriminatory variations between different COVID-19 vaccine types utilized in Iraq. The uniform immune responses observed signify the equitable efficacy and performance of these vaccines. Despite minor quantitative discrepancies, these variations do not hold statistical significance, reaffirming the notion that the various vaccines serve a similar purpose in conferring protection against COVID-19.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Imunidade Humoral , Humanos , Anticorpos Antivirais , COVID-19/prevenção & controle , Antígeno CTLA-4 , Imunidade , Imunoglobulina G , Iraque/epidemiologia , SARS-CoV-2
2.
Am J Otolaryngol ; 44(4): 103926, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37229977

RESUMO

INTRODUCTION: Minimal invasive Robotic Assisted Cochlear Implant Surgery (RACIS) is a keyhole surgery by definition. It is therefore not possible to visualize the electrode array during insertion in the scala tympani. Hitherto, surgeons visualised the round window via the external auditory canal by folding over the tympanic membrane. However, the opening of a tympanomeatal flap is not minimal invasive and is especially in conventional cochlear implantation surgery not even necessary. Here we prove that image guided and robot assisted surgery can also allow correct electrode array insertion without opening the tympanomeatal flap. AIM: The aim is to report the first experience of robotic cochlear implantation surgery fully based on image guided surgery and without the opening of a tympanomeatal flap for electrode array insertion. INTERVENTION: RACIS with a straight flexible lateral wall electrode. PRIMARY OUTCOME MEASUREMENTS: Electrode cochlear insertion depth with RACIS and autonomous inner ear access with full electrode insertion of a flexible lateral wall electrode array. SECONDARY OUTCOME MEASUREMENTS: The audiological outcome in terms of mean hearing thresholds. CONCLUSION: After a series of 33 cases and after fine-tuning the insertion angles and yet another new version of planning software to depict the round window approach, a new clinical routine for inserting electrodes fully based on image guided surgery without opening a tympanomeatal flap was developed in robotic-assisted cochlear implant surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Cóclea/cirurgia , Janela da Cóclea/cirurgia , Audição , Eletrodos Implantados
3.
Am J Otolaryngol ; 44(1): 103668, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36323158

RESUMO

AIM: To report the experience of an image-guided and navigation-based robot arm as an assistive surgical tool for cochlear implantation in a case with a labyrinthitis ossificans. PATIENT: A 55-years-old man with a history of childhood meningitis whose hearing deteriorated progressively to bilateral profound sensorineural hearing loss. INTERVENTION: Robotic Assisted Cochlear Implant Surgery (RACIS) with a straight flexible lateral wall electrode. PRIMARY OUTCOME MEASURES: Electrode cochlear insertion depth with RACIS with facial recess approach and autonomous inner ear access with full electrode insertion of a flexible straight cochlear implant array. CONCLUSIONS: Intra cochlear ossifications pose a challenge for entering the cochlea and full-length insertion of a cochlear implant. RACIS has shown that computations of radiological images combined with navigation-assisted robot arm drilling can provide efficient access to the inner ear.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Meningite , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Pessoa de Meia-Idade , Implante Coclear/métodos , Osteogênese , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Perda Auditiva Neurossensorial/etiologia , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Bilateral/cirurgia , Meningite/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...